Doprava zadarmo s Packetou nad 59.99 €
Pošta 4.49 SPS 4.99 Kuriér GLS 3.99 Zberné miesto GLS 2.99 Packeta kurýr 4.99 Packeta 2.99 SPS Parcel Shop 2.99

Implementation of New Scheme on Indian Power System for Distance Relay Operation in Zone 3 to Avoid Power System Blackout

Jazyk AngličtinaAngličtina
Kniha Brožovaná
Kniha Implementation of New Scheme on Indian Power System for Distance Relay Operation in Zone 3 to Avoid Power System Blackout Muhammah Adnan
Libristo kód: 15844031
Nakladateľstvo Grin Publishing, február 2017
Thesis (M.A.) from the year 2016 in the subject Energy Sciences, grade: Master's Degree, Hohai Unive... Celý popis
? points 125 b
49.83
Skladom u dodávateľa Odosielame za 15-20 dní

30 dní na vrátenie tovaru


Mohlo by vás tiež zaujímať


Cuaderno práctico de ejercicios antiestrés RUT ABADIA / Brožovaná
common.buy 11.59
Trust Economy PHILIPP K DIEKHONER / Brožovaná
common.buy 19.78
Islam im Morgen- und Abendland August Müller / Brožovaná
common.buy 63.56
Lehrbuch Des B rgerlichen Rechtes Bernhard Matthiaß / Brožovaná
common.buy 66.78
Child Language Reader Kate Trott / Brožovaná
common.buy 45.19

Thesis (M.A.) from the year 2016 in the subject Energy Sciences, grade: Master's Degree, Hohai University (Energy and Electrical Collage), course: Electric Power system, language: English, abstract: In July 2012 there was blackout in India. As the result of this disturbance there were two blackouts. In first blackout only the Northern Grid was affected but in the second blackout Northern, Eastern and North-Eastern grid collapsed. A committee formed by the government analyzed the events that resulted in the collapse of system and pointed out no of factors that lead to disturbance. Whole grid collapsed under load encroachment condition. In this thesis different factors have been analyzed using PSCAD simulation and solutions have been proposed. Approximate model of Indian power system has been developed in PSCAD using approximate parameters given in Grid Failure Report issued by the Indian government. Increase in installed capacity of power system and its impact on system frequency and rotor angle has been studied. A new algorithm has been proposed for distance relay operation in Zone 3 to avoid power system blackout using Indian grid model. One of the main factors that lead to the collapse of whole system was the operation of zone 3 distance relay on 400kV Bina-Gwalior Line. This scheme will improve system stability under heavy load conditions. A simplified model in PSCAD was established in order to study the zone 3 protection of distance relay.

Informácie o knihe

Celý názov Implementation of New Scheme on Indian Power System for Distance Relay Operation in Zone 3 to Avoid Power System Blackout
Jazyk Angličtina
Väzba Kniha - Brožovaná
Dátum vydania 2017
Počet strán 62
EAN 9783668386563
ISBN 3668386560
Libristo kód 15844031
Nakladateľstvo Grin Publishing
Váha 91
Rozmery 148 x 210 x 4
Darujte túto knihu ešte dnes
Je to jednoduché
1 Pridajte knihu do košíka a vyberte možnosť doručiť ako darček 2 Obratom Vám zašleme poukaz 3 Knihu zašleme na adresu obdarovaného

Prihlásenie

Prihláste sa k svojmu účtu. Ešte nemáte Libristo účet? Vytvorte si ho teraz!

 
povinné
povinné

Nemáte účet? Získajte výhody Libristo účtu!

Vďaka Libristo účtu budete mať všetko pod kontrolou.

Vytvoriť Libristo účet