Doprava zadarmo s Packetou nad 59.99 €
Pošta 4.49 SPS 4.99 Kuriér GLS 3.99 Zberné miesto GLS 2.99 Packeta kurýr 4.99 Packeta 2.99 SPS Parcel Shop 2.99

Distance Measurements between Paramagnetic Centers by High-Field EPR

Jazyk AngličtinaAngličtina
Kniha Brožovaná
Kniha Distance Measurements between Paramagnetic Centers by High-Field EPR Marloes Penning De Vries
Libristo kód: 06815228
Nakladateľstvo VDM Verlag Dr. Mueller E.K., júl 2008
The resonance frequency of an electron is highly sensitive to the local magnetic field at the electr... Celý popis
? points 165 b
65.26
Skladom u dodávateľa Odosielame za 15-20 dní

30 dní na vrátenie tovaru


Mohlo by vás tiež zaujímať


Health At Every Size Linda Bacon / Brožovaná
common.buy 12.32
Science, Strategy and War Frans P.B. Osinga / Brožovaná
common.buy 64.15
Tolstoy: The Comprehensive Vision E. B. Greenwood / Pevná
common.buy 174.94
Newman's Approach to Knowledge Lawrence Richardson / Brožovaná
common.buy 18.54
Corporate Citizenship in Kommunen Martin Sinner / Brožovaná
common.buy 49.12
PRIPRAVUJEME
Sing With The Choir Volume 4 / Brožovaná
common.buy 22.25
Automatic Item Generation Mark J Gierl / Pevná
common.buy 242.91

The resonance frequency of an electron is highly sensitive to the local magnetic field at the electron and can therefore be used as a probe of the electron's direct surroundings. Electron Paramagnetic Resonance (EPR or ESR) is a method by which this canbe studied. The presence of a nearby electron B may cause faster relaxation of electron A, which depends on the distance between the two electrons. Performing EPR relaxation measurements at highmagnetic fields (6.4 Tesla) provides the spectral resolution from which one can extract information about the distance between and orientation of electrons A and B with respect to each other. High-field EPR relaxation measurements have been performed on the electron-transfer proteins cytochrome c and cytochrome c oxidase. These proteins form a short-lived complex in which an electron is transferred from cytochrome c to its partner. The goal was todetermine the structure of this transient complex. Based onextensive analysis and simulation of the data from conventional as well as high-field EPR it is proposed in this work that the two proteins do not build a single, well-defined complex, but rather form unspecific, short-lived complexes.

Informácie o knihe

Celý názov Distance Measurements between Paramagnetic Centers by High-Field EPR
Jazyk Angličtina
Väzba Kniha - Brožovaná
Dátum vydania 2008
Počet strán 140
EAN 9783639058086
ISBN 3639058089
Libristo kód 06815228
Nakladateľstvo VDM Verlag Dr. Mueller E.K.
Váha 195
Rozmery 152 x 229 x 8

Kategórie

Darujte túto knihu ešte dnes
Je to jednoduché
1 Pridajte knihu do košíka a vyberte možnosť doručiť ako darček 2 Obratom Vám zašleme poukaz 3 Knihu zašleme na adresu obdarovaného

Prihlásenie

Prihláste sa k svojmu účtu. Ešte nemáte Libristo účet? Vytvorte si ho teraz!

 
povinné
povinné

Nemáte účet? Získajte výhody Libristo účtu!

Vďaka Libristo účtu budete mať všetko pod kontrolou.

Vytvoriť Libristo účet